37MGRA PC 00 (ODU IPM Module Protection Diagnosis and Solution)

Códigos de diagnóstico cubiertos

PC 00 (PC00)

  • PC 00 – ODU IPM Module Protection

Description: When the voltage signal the IPM sends to the compressor drive chip is abnormal, the display LED shows “PC 00” and the AC turn off. Recommended parts to prepare: Connection wires, IPM module board, Outdoor fan assembly, Compressor, Outdoor PCB Troubleshooting and repair: NOTE: For certain models, the outdoor PCB can not be removed separately. In this case, the outdoor electric control box should be replaced as a whole.

Flujo de solución de problemas

PC 00 (ODU IPM Module Protection Diagnosis and Solution) workflow
PC 00 (ODU IPM Module Protection Diagnosis and Solution) workflow

Pruebas de diagnóstico relacionadas

Fuente del flujo de trabajo: manual de servicio original 37MGRA-02SM PDF. Nombres de códigos de error contrastados con 37MGRA-04SI.