37MGRA PC 41 (Outdoor compressor current sampling circuit failure diagnosis and solution)

Códigos de diagnóstico cubiertos

PC 41

Description: Three-phase sampling offset voltage error, the static bias voltage is normally 2.5V. Recommended parts to prepare: Outdoor main PCB

Flujo de solución de problemas

PC 41 (Outdoor compressor current sampling circuit failure diagnosis and solution) workflow
PC41 (Outdoor compressor current sampling circuit failure diagnosis and solution) workflow

Pruebas de diagnóstico relacionadas

Fuente del flujo de trabajo: manual de servicio original 37MGRA-02SM PDF. Nombres de códigos de error contrastados con 37MGRA-04SI.

Desplazarse hacia arriba