{"id":158,"date":"2022-03-21T13:39:53","date_gmt":"2022-03-21T17:39:53","guid":{"rendered":"https:\/\/cetechsupport.com\/?page_id=158"},"modified":"2022-05-04T10:15:23","modified_gmt":"2022-05-04T14:15:23","slug":"ductless-videos","status":"publish","type":"page","link":"https:\/\/cetechsupport.com\/es\/ductless-videos\/","title":{"rendered":"V\u00eddeos sin ductos"},"content":{"rendered":"<p><a rel=\"noreferrer noopener\" href=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2021\/06\/CEs-Carrier-Bryant-DLS-Service-Manual.pdf\" target=\"_blank\">Carrier Enterprise Carrier &amp; Bryant Ductless Service Manual<\/a><\/p>\n\n\n\n<p><strong><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\"> NEW<\/mark><\/strong> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\"><a href=\"https:\/\/cetechsupport.com\/es\/video-40mahb-high-wall-dls-blower-assembly-removal\/\">40MAHB High Wall Blower Assembly\/Condensate pan removal:<\/a><\/mark> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">In this video you will see how to remove the blower assembly from the high wall mount unit for servicing and cleaning of the unit.<\/mark><\/p>\n\n\n\n<p><a href=\"https:\/\/cetechsupport.com\/es\/video-rectorseal-97622-safe-t-switch-ss610e-dls-condensate-shutoff-switch\/\">Rectorseal &#8211; 97622 Safe-T-Switch SS610E DLS Condensate Shutoff Switch Installation &amp; Service video:<\/a><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\"> In this video you will see how to install the condensate shutoff switch on the new 40MAHB High wall mount unit, along with resetting the switch once it has tripped.<\/mark><\/p>\n\n\n\n<p><a href=\"https:\/\/cetechsupport.com\/es\/video-accessing-the-outdoor-unit-point-check-function-for-multi-head-systems\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">Accessing the Outdoor Unit Point Check Function for Multi-head systems<\/mark><\/a>: <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">This video will show you how to use the Point Check Function on the Multi-head outdoor units to assist in troubleshooting.<\/mark><\/p>\n\n\n\n<p><a href=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2022\/03\/Multi-head-Point-Check-Function-worksheet-2.xlsx\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">Point Check Function worksheet<\/mark><\/a>:<mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\"> This is the excel file used in the video.<\/mark><\/p>\n\n\n\n<p><a href=\"https:\/\/cetechsupport.com\/es\/video-accessing-the-point-check-function-for-a-single-head-system\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">Accessing the Point Check Function for Single head systems<\/mark><\/a><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">:<\/mark> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">This video will show you how to use the Point Check Function on Single-head outdoor units to assist in troubleshooting.<\/mark><\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2020\/09\/Hexdecimal.pdf\" target=\"_blank\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">PDF file to help decode Hexadecimal Numbers<\/mark><\/a>: <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Once you have your hexadecimal number from the display. Look at this chart to convert that number to a decimal number and then multiply that number by 10 for the fan motor RPM. And for the EXV angle multiply the decimal number by 2.<\/mark><\/p>\n\n\n\n<p><a href=\"https:\/\/cetechsupport.com\/es\/video-adjusting-the-setting-on-the-indoor-unit\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">Adjusting the settings on the indoor unit<\/mark>:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">In this video we will walk thru how to access the settings menu of the indoor ductless units and adjust the temperature compensation(calibrate the temperature sensors).<\/mark><\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2020\/07\/Service-remote-0918.pdf\" target=\"_blank\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">RG57 Wireless Remote Controller Service Manual:<\/mark><\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">This is the service manual for the wireless remote controllers. It has information on how to check system settings and the indoor unit Point Check Function.<\/mark><\/p>\n\n\n\n<p><a href=\"https:\/\/cetechsupport.com\/es\/video-of-using-the-rg10-remote-to-enter-the-setup-menu\/\">Adjusting the settings on the indoor unit with the RG10 remote:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">In this video we will walk thru how to access the settings menu of the indoor ductless units. In this example you can shut off the indoor fan in heat mode but also adjust all other settings and adjust the temperature compensation(calibrate the temperature sensors).<\/mark> Follow the instructions to the letter for it to work as described.<\/p>\n\n\n\n<p><a href=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2022\/03\/SG-RG10-01.pdf\">RG10 Wireless Remote Controller Service Manual:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">This is the service manual for the wireless remote controllers. It has information on how to check system settings and the indoor unit Point Check Function.<\/mark><\/p>\n\n\n\n<p><a rel=\"noreferrer noopener\" href=\"https:\/\/cetechsupport.com\/es\/video-dr-smart-user-guide\/\" target=\"_blank\">Dr. Smart DLS Diagnostic Tool PN#17222000A55927:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">This video will show you how to use the Dr. Smart DLS diagnostic tool and provide insight into the capabilities of the tools use, when troubleshooting a DLS system.<\/mark> This can be purchased at any Carrier Enterprise Service\/Part Center location.<\/p>\n\n\n\n<p><a href=\"https:\/\/cetechsupport.com\/es\/video-e1-communication-fault-code\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">E1 Communication Fault Code<\/mark>:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">The video covers the steps needed to take to troubleshoot a communication fault code and check the S-wire.<\/mark><\/p>\n\n\n\n<p><a href=\"https:\/\/cetechsupport.com\/es\/video-ipm-malfunction-p0-p4-or-p6-code\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">IPM Malfunction P0, P4, or P6 code<\/mark>:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Depending on your unit this video will walk you thru the steps to troubleshoot the system<\/mark>.<\/p>\n\n\n\n<p><a href=\"https:\/\/cetechsupport.com\/es\/video-indoor-outdoor-fan-motors-e3-e8-or-f5-code\/\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\">Indoor\/Outdoor Fan Motors E3, E8, F5 code<\/mark>:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Depending on your unit this videos will walk you thru the steps to troubleshoot the different types of Indoor and Outdoor fan motors on Ductless systems.<\/mark><\/p>\n\n\n\n<p class=\"has-black-color has-text-color\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\"><a href=\"https:\/\/cetechsupport.com\/es\/video-the-diamond-pump-installation\/\">Diamond Pump Installation<\/a>:<\/mark>\u00a0<mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">This video details the steps needed to correctly install a Blue Diamond pump in a Carrier Ductless high wall air handler.\u00a0<\/mark><\/p>","protected":false},"excerpt":{"rendered":"<p>Carrier Enterprise Carrier &amp; Bryant Ductless Service Manual NEW 40MAHB High Wall Blower Assembly\/Condensate pan removal: In this video you will see how to remove the blower assembly from the high wall mount unit for servicing and cleaning of the unit. Rectorseal &#8211; 97622 Safe-T-Switch SS610E DLS Condensate Shutoff Switch Installation &amp; Service video: In [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-158","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Josh Goodman","author_link":"https:\/\/cetechsupport.com\/es\/author\/joshg\/"},"uagb_comment_info":0,"uagb_excerpt":"Carrier Enterprise Carrier &amp; Bryant Ductless Service Manual NEW 40MAHB High Wall Blower Assembly\/Condensate pan removal: In this video you will see how to remove the blower assembly from the high wall mount unit for servicing and cleaning of the unit. Rectorseal &#8211; 97622 Safe-T-Switch SS610E DLS Condensate Shutoff Switch Installation &amp; Service video: In&hellip;","_links":{"self":[{"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/pages\/158","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/comments?post=158"}],"version-history":[{"count":4,"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/pages\/158\/revisions"}],"predecessor-version":[{"id":1682,"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/pages\/158\/revisions\/1682"}],"wp:attachment":[{"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/media?parent=158"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}