{"id":170,"date":"2022-03-21T13:54:18","date_gmt":"2022-03-21T17:54:18","guid":{"rendered":"https:\/\/cetechsupport.com\/?page_id=170"},"modified":"2026-08-15T14:26:37","modified_gmt":"2026-08-15T18:26:37","slug":"sistemas-de-velocidad-variable","status":"publish","type":"page","link":"https:\/\/cetechsupport.com\/es\/variable-speed-systems\/","title":{"rendered":"Sistemas de velocidad variable"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/video-del-kit-protector-contra-sobretensiones-y-monitor-de-rango-de-voltaje-rectorseal-rsh-50-vrm\/\">Kit Protector de Sobretensi\u00f3n\/Monitor de Rango de Voltaje Rectorseal RSH 50 VRM<\/a>En este video ver\u00e1s c\u00f3mo configurar el Protector contra Sobretensiones\/Monitor de Rango de Voltaje Rectorseal RSH 50 VRM KIT<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2026\/07\/RSH-50-VRM-KIT.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Instrucciones de instalaci\u00f3n del kit protector de sobretensi\u00f3n\/monitor de rango de voltaje Rectorseal RSH 50 VRM<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-vivid-red-color\"><a href=\"https:\/\/cetechsupport.com\/es\/recuperacion-de-codigos-de-falla-de-video\/\">Recuperaci\u00f3n de c\u00f3digos de falla<\/a>: <\/mark><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Este video te mostrar\u00e1 c\u00f3mo obtener los c\u00f3digos de falla de la interfaz de usuario para ayudar a solucionar problemas del sistema.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/recuperacion-de-codigo-de-falla-de-video-forzado\/\">Recuperaci\u00f3n forzada de c\u00f3digos de falla:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Este video te mostrar\u00e1 c\u00f3mo colocar la unidad exterior en una recuperaci\u00f3n forzada de c\u00f3digos en caso de que tu unidad no est\u00e9 reportando c\u00f3digos de falla, pero no est\u00e9 operando cuando se le indica.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/video-charging-with-the-user-interface\/\">Carga con la Interfaz de Usuario:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Este video te mostrar\u00e1 los 2 m\u00e9todos para cargar un sistema de velocidad variable y c\u00f3mo navegar la interfaz de usuario para cargar.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/video-airflow-verification-test\/\">Prueba de Verificaci\u00f3n de Flujo de Aire:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Esto te guiar\u00e1 a trav\u00e9s de c\u00f3mo ingresar la interfaz de usuario en el proceso de verificaci\u00f3n de Airflow para comprobar la presi\u00f3n est\u00e1tica del conducto y las RPM del motor del ventilador.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/video-de-la-operacion-de-evacuacion-y-rescate\/\">Operaci\u00f3n de recuperaci\u00f3n y evacuaci\u00f3n:<\/a><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\"> Esto te guiar\u00e1 para navegar por el men\u00fa de servicio y asegurarte de que el EXV est\u00e9 abierto para que puedas garantizar que todo el refrigerante sea extra\u00eddo del sistema para una reparaci\u00f3n de refrigerante.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/codigo-de-comunicacion-de-solucion-de-problemas-de-video-16\/\">C\u00f3digo 16 Fallo de comunicaci\u00f3n:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Este video le mostrar\u00e1 c\u00f3mo solucionar problemas en el circuito de comunicaci\u00f3n.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/video-how-to-use-the-user-interface-as-a-service-tool\/\">C\u00f3mo usar la Interfaz de Usuario como una Herramienta de Servicio:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">En este video te mostraremos c\u00f3mo puedes usar una segunda interfaz de usuario como herramienta para ayudarte a reducir el tiempo en una llamada de servicio.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/video-model-plug-code-25\/\">Falla en el enchufe del modelo de c\u00f3digo 25:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Este video cubrir\u00e1 c\u00f3mo probar el enchufe del modelo.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/video-code-41\/\">C\u00f3digo 41<\/a>&nbsp;<mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Fallo en el motor del ventilador<\/mark> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Este proceso tambi\u00e9n funciona en el Fan Coil FE4.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/operacion-de-proteccion-de-alta-presion-de-video\/\">Operaci\u00f3n de protecci\u00f3n de alta presi\u00f3n:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Esto explica c\u00f3mo opera la protecci\u00f3n de alto nivel en el Sistema de Nueva Generaci\u00f3n.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/operacion-de-proteccion-por-baja-presion-del-video\/\">Operaci\u00f3n de protecci\u00f3n contra baja presi\u00f3n:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Esto explica c\u00f3mo opera la protecci\u00f3n de alto nivel en el Sistema de Nueva Generaci\u00f3n.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/prueba-de-transductor-de-presion-en-video\/\">Prueba de transductores de presi\u00f3n:<\/a><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\"> Esto te mostrar\u00e1 c\u00f3mo verificar un transductor de presi\u00f3n.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/solucion-de-problemas-y-pruebas-de-valvulas-de-expansion-electronicas-en-video\/\">Soluci\u00f3n de problemas y pruebas de EXV:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Aqu\u00ed te guiaremos para medir la resistencia del motor paso a paso y luego probaremos la v\u00e1lvula para asegurarnos de que funcione mec\u00e1nicamente.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/video-thermistor-testing\/\">Prueba de termistor:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Los c\u00f3digos 51-54 se relacionan con un problema de termistor.<\/mark><\/p>\n\n\n\n<section class=\"wp-block-uagb-columns uagb-columns__wrap uagb-columns__stack-mobile uagb-columns__valign- uagb-columns__gap-10 align uagb-block-f3c8742c uagb-columns__columns-2 uagb-columns__max_width-theme\"><div class=\"uagb-columns__overlay\"><\/div><div class=\"uagb-columns__inner-wrap uagb-columns__columns-2\">\n<div class=\"wp-block-uagb-column uagb-column__wrap uagb-column__background-undefined uagb-block-cea28ac7\"><div class=\"uagb-column__overlay\"><\/div>\n<p class=\"has-text-align-center wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2026\/08\/10-k-ohm-chart-TempVsResistChart.pdf\" data-type=\"link\" data-id=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2026\/08\/10-k-ohm-chart-TempVsResistChart.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Gr\u00e1fico de 10K ohms<\/a> <span class=\"has-inline-color has-black-color\">\u2013 El gr\u00e1fico ayuda a convertir ohmios a temperatura Fahrenheit<\/span><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-column uagb-column__wrap uagb-column__background-undefined uagb-block-3a527ac8\"><div class=\"uagb-column__overlay\"><\/div>\n<p class=\"has-text-align-center wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2026\/08\/10-k-ohm-chart-TempVsResistChart.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Gr\u00e1fico de 50K ohms<\/a> <span class=\"has-inline-color has-black-color\">\u2013 El gr\u00e1fico ayuda a convertir ohmios a temperatura Fahrenheit<\/span><\/p>\n<\/div>\n<\/div><\/section>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/es\/video-solucion-de-problemas-motor-de-ventilador-condensador-de-proxima-generacion\/\">Motor de ventilador condensador de pr\u00f3xima generaci\u00f3n:<\/a> <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Este video te mostrar\u00e1 c\u00f3mo probar el motor del ventilador del condensador de pr\u00f3xima generaci\u00f3n. Es diferente al motor del condensador de 5 etapas.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2022\/04\/Troubleshooting-FV-FK-ECM-Motors-X13-Motors.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Soluci\u00f3n de problemas del motor ECM FV\/FK y el motor X13: <\/a><mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Esta gu\u00eda te ayudar\u00e1 a solucionar problemas de los motores de Velocidad Variable y X-13 de 16 pines.<\/mark><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/cetechsupport.com\/wp-content\/uploads\/2022\/04\/Inverter-Code-69-77.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Bombas de calor Code 69 25VNA0\/280ANV, unidades de aire acondicionado 24VNA\/180CNV<\/a>; <mark style=\"background-color:rgba(0, 0, 0, 0)\" class=\"has-inline-color has-black-color\">Primero revise los devanados del compresor y a tierra en la cabeza terminal del compresor. Esta prueba ayudar\u00e1 a verificar si el compresor est\u00e1 trabado. Si la placa genera un c\u00f3digo 79 con el compresor desconectado, entonces es muy probable que el compresor est\u00e9 trabado.<\/mark><\/p>","protected":false},"excerpt":{"rendered":"<p>Rectorseal RSH 50 VRM KIT Surge Protector\/Voltage Range Monitor Kit: In this video you will see how to setup the Rectorseal RSH 50 VRM KIT Surge Protector\/Voltage Range Monitor Kit Rectorseal RSH 50 VRM KIT Surge Protector\/Voltage Range Monitor Kit Installation Instructions Fault Code Retrieval: This video will show you how to get the fault [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"class_list":["post-170","page","type-page","status-publish","hentry"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Carrier Enterprise","author_link":"https:\/\/cetechsupport.com\/es\/author\/joshg\/"},"uagb_comment_info":0,"uagb_excerpt":"Rectorseal RSH 50 VRM KIT Surge Protector\/Voltage Range Monitor Kit: In this video you will see how to setup the Rectorseal RSH 50 VRM KIT Surge Protector\/Voltage Range Monitor Kit Rectorseal RSH 50 VRM KIT Surge Protector\/Voltage Range Monitor Kit Installation Instructions Fault Code Retrieval: This video will show you how to get the fault&hellip;","_links":{"self":[{"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/pages\/170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/comments?post=170"}],"version-history":[{"count":15,"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/pages\/170\/revisions"}],"predecessor-version":[{"id":52313,"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/pages\/170\/revisions\/52313"}],"wp:attachment":[{"href":"https:\/\/cetechsupport.com\/es\/wp-json\/wp\/v2\/media?parent=170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}