{"id":10008,"date":"2026-08-21T18:14:01","date_gmt":"2026-08-21T22:14:01","guid":{"rendered":"https:\/\/cetechsupport.com\/?p=10008"},"modified":"2026-08-21T18:24:59","modified_gmt":"2026-08-21T22:24:59","slug":"code-25-24-configuration-du-modele-modifiee","status":"publish","type":"post","link":"https:\/\/cetechsupport.com\/fr\/code-25-24-model-configuration-changed\/","title":{"rendered":"Code 25-24 Configuration du mod\u00e8le modifi\u00e9e"},"content":{"rendered":"<div class=\"wp-block-group fault-code-summary is-layout-flow wp-block-group-is-layout-flow\"><div class=\"wp-block-group__inner-container\">\n<h2 class=\"wp-block-heading\">Code 25-24 Configuration du mod\u00e8le modifi\u00e9e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>25-24<\/strong><\/p>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Le code 25-24 indique qu'il y a une incompatibilit\u00e9 entre la configuration du mod\u00e8le stock\u00e9e en m\u00e9moire et le connecteur de mod\u00e8le physique actuellement install\u00e9. Le code 25-24 est d\u00e9fini lorsque l'\u00e9quipement est mis sous tension avec une valeur de connecteur de mod\u00e8le physique valide qui diff\u00e8re de la valeur de configuration du mod\u00e8le valide stock\u00e9e en m\u00e9moire. Le code 25-24 peut \u00e9galement \u00eatre d\u00e9fini lorsqu'un connecteur de mod\u00e8le physique invalide est install\u00e9 et qu'une configuration de mod\u00e8le valide est stock\u00e9e en m\u00e9moire. Une modification de la configuration du mod\u00e8le n'affectera la configuration de commande que si un connecteur de mod\u00e8le physique \u00e9tait pr\u00e9sent lors de la mise sous tension de l'\u00e9quipement ou si la configuration du mod\u00e8le a \u00e9t\u00e9 d\u00e9finie \u00e9lectroniquement. Le code 25-24 sera d\u00e9fini si un connecteur de mod\u00e8le physique est remplac\u00e9 par une autre valeur valide ou par une valeur invalide alors que l'appareil est sous tension. Si le changement de connecteur de mod\u00e8le physique est intentionnel, aucune action corrective n'est requise. Laissez le nouveau connecteur de mod\u00e8le en place et le code s'effacera de lui-m\u00eame lorsque l'alimentation sera coup\u00e9e puis r\u00e9tablie sur l'\u00e9quipement. Si le changement de connecteur de mod\u00e8le n'est pas intentionnel, coupez l'alimentation de l'\u00e9quipement, installez le connecteur de mod\u00e8le correct et remettez l'\u00e9quipement sous tension. Alternativement, le connecteur physique pourrait \u00eatre retir\u00e9 et la configuration du mod\u00e8le d\u00e9finie \u00e9lectroniquement via l'Infinity System Control, l'application Service Tech ou les micro-interrupteurs (DIP switches).<\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\"><em>Pages de d\u00e9pannage ACHPVSR454-02SM.<\/em><\/p>","protected":false},"excerpt":{"rendered":"<p>Troubleshooting guidance for fault code(s) 25-24.<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[88],"tags":[97],"class_list":["post-10008","post","type-post","status-publish","format-standard","hentry","category-fault-code-troubleshooting","tag-fault-code-25-24"],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Carrier Enterprise","author_link":"https:\/\/cetechsupport.com\/fr\/author\/joshg\/"},"uagb_comment_info":0,"uagb_excerpt":"Troubleshooting guidance for fault code(s) 25-24.","_links":{"self":[{"href":"https:\/\/cetechsupport.com\/fr\/wp-json\/wp\/v2\/posts\/10008","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cetechsupport.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cetechsupport.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cetechsupport.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cetechsupport.com\/fr\/wp-json\/wp\/v2\/comments?post=10008"}],"version-history":[{"count":2,"href":"https:\/\/cetechsupport.com\/fr\/wp-json\/wp\/v2\/posts\/10008\/revisions"}],"predecessor-version":[{"id":930458,"href":"https:\/\/cetechsupport.com\/fr\/wp-json\/wp\/v2\/posts\/10008\/revisions\/930458"}],"wp:attachment":[{"href":"https:\/\/cetechsupport.com\/fr\/wp-json\/wp\/v2\/media?parent=10008"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cetechsupport.com\/fr\/wp-json\/wp\/v2\/categories?post=10008"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cetechsupport.com\/fr\/wp-json\/wp\/v2\/tags?post=10008"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}