37MUHA Fault Codes EH 00, EH 0A, EC 51 – EEPROM Malfunction
The indoor or outdoor PCB main chip does not receive feedback from the EEPROM chip.
37MUHA Fault Codes EH 00, EH 0A, EC 51 – EEPROM Malfunction Read More »
The indoor or outdoor PCB main chip does not receive feedback from the EEPROM chip.
37MUHA Fault Codes EH 00, EH 0A, EC 51 – EEPROM Malfunction Read More »
The indoor unit cannot communicate with the outdoor unit.
37MUHA Fault Code EL 01 – Indoor and Outdoor Unit Communication Error Read More »
The outdoor main PCB cannot detect the IPM board.
37MUHA Fault Code PC 40 – ODU Main Chip and Compressor Drive Communication Error Read More »
The outdoor compressor current sampling circuit has an abnormal offset voltage.
37MUHA Fault Code PC 41 – Compressor Current Sampling Circuit Failure Read More »
One or more compressor phase currents are abnormally low.
37MUHA Fault Code PC 43 – ODU Compressor Phase Loss Protection Read More »
The PCB does not receive normal zero-crossing signal feedback.
37MUHA Fault Code EH 02 – Zero Crossing Detection Error Read More »
The inverter module IR chip has detected an internal parameter error.
37MUHA Fault Code PC 45 – ODU IR Chip Drive Failure Read More »
Indoor or outdoor fan speed remains too low or too high for a specified time.
37MUHA Fault Codes EH 03, EC 07, EC 71 – Fan Speed Outside Normal Range Read More »
Compressor discharge temperature protection is active.
37MUHA Fault Code PC 06 – Compressor Discharge Temperature Protection Read More »
The suction transducer sampling voltage is outside its expected range.
37MUHA Fault Code EC 5C – Suction Transducer Open or Short Circuit Read More »