37MGRA PC 04 (Inverter Compressor Drive Error Diagnosis and Solution)

Códigos de diagnóstico cubiertos

PC 04, PC04

  • PC 04 – Inverter Compressor Drive Error

Description: An abnormal inverter compressor drive is detected by a special detection circuit, including communication signal detection, voltage detection, compressor rotation speed signal detection and so on. Recommended parts to prepare: Connection wires, IPM module board, Outdoor fan assembly, Compressor, Outdoor PCB Troubleshooting and repair: YES NO NO YES NO YES NO YES

Flujo de solución de problemas

PC 04 (Inverter Compressor Drive Error Diagnosis and Solution) workflow
PC 04 (Inverter Compressor Drive Error Diagnosis and Solution) workflow

Pruebas de diagnóstico relacionadas

Fuente del flujo de trabajo: manual de servicio original 37MGRA-02SM PDF. Nombres de códigos de error contrastados con 37MGRA-04SI.

Desplazarse hacia arriba