37MGRA PC 06 (Discharge temperature protection of compressor diagnosis and solution)

Códigos de diagnóstico cubiertos

PC 06

Description: When the compressor discharge temperature (TP) is more than 115oC for 10 seconds, the compressor ceases operation and does not restart until TP is less than 90oC Recommended parts to prepare: Connection wires, Outdoor PCB, Discharge temperature sensor, Refrigerant Troubleshooting and repair:

Flujo de solución de problemas

PC 06 (Discharge temperature protection of compressor diagnosis and solution) workflow
PC06 (Discharge temperature protection of compressor diagnosis and solution) workflow

Pruebas de diagnóstico relacionadas

Fuente del flujo de trabajo: manual de servicio original 37MGRA-02SM PDF. Nombres de códigos de error contrastados con 37MGRA-04SI.