37MGRA PC 0L (Low Ambient Temperature Protection)

Códigos de diagnóstico cubiertos

PC 0L

  • PC 0L – Low Ambient Temperature Protection

Description: It is a protection function. When compressor is off, outdoor ambient temperature(T4) is lower than -35oC. for 10s, the AC will stop and display the failure code. When compressor is on, outdoor ambient temperature(T4) is lower than -40oC.for 10s, the AC will stop and display the failure code. When outdoor ambient temperature(T4) is no lower than -32oC.for 10s, the unit will exit protection

Flujo de solución de problemas

PC 0L (Low Ambient Temperature Protection) workflow
PC0L (Low Ambient Temperature Protection) workflow

Pruebas de diagnóstico relacionadas

Fuente del flujo de trabajo: manual de servicio original 37MGRA-02SM PDF. Nombres de códigos de error contrastados con 37MGRA-04SI.