Gas Furnace Diagnostic Report Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.Contact et routage – Étape 1 of 10Gas Furnace Diagnostic Report This form follows the furnace sequence of operation and collects the measurements, observations, and evidence needed for Carrier Enterprise Technical Service & Support to assist with diagnosis. Safety: Follow all manufacturer instructions and applicable codes. Stop operation and follow appropriate safety procedures for suspected gas leaks, unsafe combustion, flame rollout, elevated carbon monoxide, venting failure, or other hazardous conditions. Veuillez sélectionner votre région. *— Sélectionner un choix —Grandes Plaines (Dakota du Nord, Dakota du Sud, Nebraska, Kansas, Iowa, Missouri)Floride (FL)Mid-Atlantic (MD, VA, WV, Washington D.C.)Nord-Est (CT, NJ, NY, PA)Sud-Est (NC, SC, TN, MS)Centre-Sud/Sud du Texas (TX, OK, AR, LA)CanadaNom du concessionnaire / de l'entreprise *Numéro de compte du concessionnaire *Nom du technicien *PremièrementDernierTechnicien de téléphonie mobile *E-mail du technicien *Are you currently at the job site? *OuiNonTravaillez-vous actuellement avec un représentant du support technique ? *OuiNonNuméro de dossier ou nom du représentant du support techniqueSuivantEnregistrer et reprendre plus tardChantier / Informations clientChantier / Nom du client *Chantier / Adresse du client *Adresse Ligne 1Ligne d'adresse 2VilleÉtat / Province / RégionCode postal— Sélectionner country —AfghanistanAlbanieAlgérieSamoa américainesAndorreAngolaAnguillaAntarctiqueAntigua-et-BarbudaArgentineArménieArubaAustralieAutricheAzerbaïdjanBahamasBahreïnBangladeshLa BarbadeBiélorussieBelgiqueBelizeBéninBermudesBhoutanÉtat plurinational de BolivieBonaire, Saint-Eustache et SabaBosnie-HerzégovineBotswanaÎle BouvetBrésilTerritoire britannique de l'océan IndienBrunei DarussalamBulgarieBurkina FasoBurundiCap-VertCambodgeCamerounCanadaÎles CaïmansRépublique centrafricaineTchadChiliChineÎle ChristmasÎles Cocos (Keeling)ColombieComoresCongoCongo (République démocratique du)Îles CookCosta RicaCroatieCubaCuraçaoChypreRépublique tchèqueCôte d'IvoireDanemarkDjiboutiDominiqueRépublique dominicaineÉquateurÉgypteEl SalvadorGuinée équatorialeÉrythréeEstonieEswatini (Royaume d')ÉthiopieÎles MalouinesÎles FéroéFidjiFinlandeFranceGuyane françaisePolynésie françaiseTerres australes et antarctiques françaisesGabonGambieGéorgieAllemagneGhanaGibraltarGrèceGroenlandGrenadeGuadeloupeGuamGuatemalaGuerneseyGuinéeGuinée-BissauGuyanaHaïtiÎles Heard-et-MacDonaldHondurasHong KongHongrieIslandeIndeIndonésieIran (République islamique d')IrakIrlande (République d')Île de ManIsraëlItalieJamaïqueJaponJerseyJordanieKazakhstanKenyaKiribatiCorée (République populaire démocratique de)Corée (République de)KosovoKoweïtKirghizstanRépublique démocratique populaire laoLettonieLibanLesothoLiberiaLibyeLiechtensteinLituanieLuxembourgMacaoMadagascarMalawiMalaisieMaldivesMaliMalteÎles MarshallMartiniqueMauritanieMauriceMayotteMexiqueMicronésie (États fédérés de)République de MoldavieMonacoMongolieMonténégroMontserratMarocMozambiqueBirmanieNamibieNauruNépalPays-BasNouvelle-CalédonieNouvelle-ZélandeNicaraguaNigerNigeriaNiueÎle NorfolkMacédoine du Nord (République de)Îles Mariannes du NordNorvègeOmanPakistanPalaosPalestine (État de)PanamaPapouasie-Nouvelle-GuinéeParaguayPérouPhilippinesPitcairnPolognePortugalPorto RicoQatarRoumanieFédération de RussieRwandaRéunionSaint-BarthélemySainte-Hélène, Ascension et Tristan da CunhaSaint-Kitts-et-NevisSainte-LucieSaint-Martin (partie française)Saint-Pierre-et-MiquelonSaint-Vincent-et-les-GrenadinesSamoaSaint-MarinSao Tomé-et-PrincipeArabie saouditeSénégalSerbieSeychellesSierra LeoneSingapourSaint-Martin (partie néerlandaise)SlovaquieSlovénieÎles SalomonSomalieAfrique du SudGéorgie du Sud-et-les Îles Sandwich du SudSoudan du SudEspagneSri LankaSoudanSurinameSvalbard et Jan MayenSuèdeLa SuisseRépublique arabe syrienneTaïwan, République de ChineTadjikistanTanzanie (République-Unie de)ThaïlandeTimor orientalTogoTokelauTongaTrinité-et-TobagoTunisieTurkménistanÎles Turques-et-CaïquesTuvaluTurquieOugandaUkraineÉmirats arabes unisRoyaume-Uni de Grande-Bretagne et d'Irlande du NordÎles mineures éloignées des États-UnisÉtats-Unis d'AmériqueUruguayOuzbékistanVanuatuCité du VaticanVenezuela (République bolivarienne du)Viêt NamÎles Vierges britanniquesÎles Vierges des États-UnisWallis-et-FutunaSahara occidentalYémenZambieZimbabweÎles ÅlandPaysDate d'installation / de mise en serviceConcern / Failure Date *Furnace Identification & Rating PlateFurnace Brand *— Sélectionner un choix —TransporteurBryantWeathermakerFurnace Model Number *Furnace Serial Number *Furnace Configuration *Single StageTwo StageModulatingFuel *Natural GasPropaneConversion Kit Part Number *Enter the installed approved conversion kit part number.Conversion Label and Instructions Verified? *OuiNonFurnace Application *— Sélectionner un choix —Furnace OnlyFurnace with Air ConditionerDual Fuel with Heat PumpFurnace Orientation *— Sélectionner un choix —UpflowDownflowHorizontal LeftHorizontal RightThermostat / Control Type *— Sélectionner un choix —Conventional 24-V ThermostatCommunicating ControlThird-Party Communicating / InterfaceAutreIs the system zoned? *OuiNonZoning Panel / Control ModelInstalled AccessoriesHumidificateurDéshumidificateurElectronic Air CleanerUV DeviceFresh-Air VentilatorAutrePrevious Service History / Parts Already ReplacedFurnace Nameplate and Installation Photos Glisser-déposer des fichiers, Sélectionner des fichiers à télécharger Vous pouvez télécharger jusqu'à 6 fichiers. Upload clear model/serial, rating plate, conversion label, furnace installation, and control-board photos.PrécédentSuivantEnregistrer et reprendre plus tardReported ConcernSelect all concerns that apply. *No Heat / Furnace Will Not StartIntermittent Operation / LockoutInsufficient HeatExcessive Temperature Rise / Limit TripsNoiseOdorCombustion / Flame ConcernVenting ConcernCondensate ConcernAutreDescribe the concern in the technician’s own words. *Current Active Fault CodeStored / Previous Fault CodesWhere does the furnace sequence stop? *— Sélectionner un choix —Call for Heat / Control InputControl Board / Safety CheckInducer StartPressure Switch ProvingIgniter OperationGas Valve EnergizingBurner Ignition / Cross-LightingFlame ProvingIndoor Blower OperationHeating Cycle / Limit OperationStage Transition / ModulationSequence Completes — Concern Occurs During OperationUnable to DetermineIs an unsafe condition suspected? *Yes — Operation StoppedNonUnsureDescribe the suspected unsafe condition. *Fault-Code and Control-Board Evidence Glisser-déposer des fichiers, Sélectionner des fichiers à télécharger Vous pouvez télécharger jusqu'à 6 fichiers. Upload fault-code displays, board status, wiring, thermostat/control, and relevant video or photos.PrécédentSuivantEnregistrer et reprendre plus tardPower, Controls & Call for HeatLine Voltage at Furnace (VAC)Equipment Ground Verified? *OuiNonNot TestedTransformer Primary Voltage (VAC) *Transformer Secondary Voltage (VAC) *R to C Voltage (VAC) *W1 to C Voltage During Heat Call (VAC) *W2 to C Voltage During Heat Call (VAC)Control Fuse Condition *BienOpen / FailedNot TestedValid Call for Heat Confirmed at Furnace? *OuiNonNot TestedControl Board Powered and Responding? *OuiNonIntermittentNot TestedControl Board Status / LED IndicationFactory Wiring Verified Against Furnace Wiring Diagram? *OuiNonNot CompletedWas a failure identified in this section? *OuiNonPower / Control Failure Details *PrécédentSuivantEnregistrer et reprendre plus tardInducer & Pressure-Switch SequenceDoes the inducer receive an operating command? *OuiNonNot TestedInducer Voltage While Commanded (VAC)Does the inducer start and remain running? *OuiNonIntermittentNot TestedInducer Operating Amperage (A) *Measured Draft / Negative Pressure at Pressure Switch (in. wc.) *Pressure Switch Open Before Inducer Starts? *OuiNonNot TestedPressure Switch Closes After Inducer Starts? *OuiNonIntermittentNot TestedVenting, Intake & CondensateVent Material *— Sélectionner un choix —PVC / CPVC / PolypropyleneMetal B-VentChimney / LinerAutreVent Diameter and Configuration *Approximate Equivalent Vent Length (ft) *Vent / Intake Termination and Installation ObservationsVent or Intake Restriction / Recirculation Suspected? *OuiNonNot DeterminedCondensate Trap and Drain Condition *Clear / Properly InstalledRestricted / ImproperNot ApplicableNot TestedCondensate Trap Primed and Collector / Tubing Clear? *OuiNonNot ApplicableNot TestedWas a failure identified in this section? *OuiNonInducer / Venting / Condensate Failure Details *Venting, Pressure, and Condensate Evidence Glisser-déposer des fichiers, Sélectionner des fichiers à télécharger Vous pouvez télécharger jusqu'à 8 fichiers. Upload manometer readings, vent/intake termination, condensate trap, tubing, collector, and installation photos.PrécédentSuivantEnregistrer et reprendre plus tardIgnition, Gas Valve & Flame ProvingIs the igniter energized? *OuiNonNot TestedIgniter Voltage While Energized (VAC) *Igniter Resistance (Ω) *Igniter Condition *Glows / Sparks NormallyWeak / Damaged / ContaminatedNo OperationNot TestedIs the gas valve energized? *OuiNonNot TestedGas Valve Voltage During Ignition Trial (VAC)Do all burners ignite and cross-light correctly? *OuiNonIntermittentNot TestedBurner Flame / Cross-Lighting ObservationsFlame-Sensor Current (µA DC)Does flame prove and remain established? *OuiNonIntermittentNot TestedSeconds Until Flame Loss or LockoutGas Pressure & CombustionCombustion-Test Status *— Sélectionner un choix —CompletedNot Required for This ConcernUnable — Burners Will Not OperateUnable — Unsafe to OperateUnable — OtherCombustion testing is required for combustion, odor, venting, rollout, and limit concerns.Explain Why Combustion Testing Was Not Completed *Measured Inlet Gas Pressure — Furnace Off (in. wc.)Measured Inlet Gas Pressure — Operating (in. wc.)Measured Low-Stage Manifold Pressure (in. wc.)Measured High-Stage / Single-Stage Manifold Pressure (in. wc.)O₂ (%)CO₂ (%)Carbon Monoxide — Air Free (ppm)Flue Temperature (°F)Draft / Vent Pressure (in. wc.)Excess Air (%)Combustion Efficiency (%)Combustion Analyzer and Manometer Results Glisser-déposer des fichiers, Sélectionner des fichiers à télécharger Vous pouvez télécharger jusqu'à 8 fichiers. Upload analyzer printouts/screens, manometer readings, burner/flame photos, and gas-pressure evidence.Was a failure identified in this section? *OuiNonIgnition / Gas / Combustion Failure Details *PrécédentSuivantEnregistrer et reprendre plus tardIndoor Blower & AirflowDoes the indoor blower start and remain operating? *OuiNonIntermittentNot TestedBlower Motor Type *— Sélectionner un choix —PSCConstant Torque ECMVariable-Speed ECMIndéterminéHeating Airflow / Speed / Tap / Command SettingBlower Voltage (VAC) *Blower Operating Amperage (A)Pression statiqueReturn Static Pressure (in. wc.)Supply Static Pressure (in. wc.)Static Pressure After Furnace / Before Coil (in. wc.)Static Pressure After Coil (in. wc.)Total External Static Pressure — TESP (in. wc.)Filter Pressure Drop (in. wc.)Measured or Calculated Airflow (CFM)Static Pressure ReviewAutomatically compares TESP with the entered rated maximum.Temperature Rise & Limit OperationReturn-Air Temperature (°F)Supply-Air Temperature (°F)Calculated Temperature Rise (°F)Supply-air temperature minus return-air temperature.Temperature-Rise ReviewAutomatically compares calculated rise with the entered nameplate range.Limit-Switch Status During Test *Remains ClosedOpens / TripsIntermittentNot TestedLimit, Rollout, Airflow, Filter, or Duct ObservationsAirflow, Static Pressure, and Temperature Evidence Glisser-déposer des fichiers, Sélectionner des fichiers à télécharger Vous pouvez télécharger jusqu'à 8 fichiers. Upload manometer readings, temperature probes, filter, blower, coil, duct, and airflow evidence.Was a failure identified in this section? *OuiNonBlower / Airflow / Temperature-Rise Failure Details *Continue collecting the remaining operating data? *OuiNo — Continue to final reportPrécédentSuivantEnregistrer et reprendre plus tardTwo-Stage / Modulating OperationThis section appears only for two-stage or modulating furnaces.Does low-stage operation function correctly? *OuiNonIntermittentNot TestedDoes high-stage operation function correctly? *OuiNonIntermittentNot TestedDoes the furnace transition between stages correctly? *OuiNonIntermittentNot TestedLow-Stage Measured Temperature Rise (°F)High-Stage Measured Temperature Rise (°F)Low-Stage Measured Airflow (CFM)High-Stage Measured Airflow (CFM)Observed Modulation Command / Capacity (%)Stage / Modulation / Communication Observations Observed (VAC) your PrécédentSuivantEnregistrer et reprendre plus tardDiagnostic Handoff to Technical SupportReview the calculated measurement checks below. These checks compare only against the rating-plate limits entered in this form. They do not replace manufacturer service instructions or a complete safety evaluation. Measurements Not Obtained and WhyTechnician Observations / Suspected CauseTests, Adjustments, or Repairs Already PerformedEquipment Operating Status When Technician Leaves *— Sélectionner un choix —Operating NormallyOperating but Concern RemainsShut Down for SafetyNot OperatingIntermittent / Unable to ConfirmIs Immediate Technical Support Contact Requested? *OuiNonDiagnostic Measurement SummaryAutomatically populated from the calculated comparisons.Additional Installation / Diagnostic Photos or Videos Glisser-déposer des fichiers, Sélectionner des fichiers à télécharger Vous pouvez télécharger jusqu'à 10 fichiers. Upload any remaining evidence that will help Technical Support evaluate the furnace.Technician Confirmation *I confirm the entered measurements were taken from this equipment and the report is complete to the extent testing could be safely performed.After submission, the report will be routed to the selected regional Technical Service & Support team. A copy will be emailed to the technician, and an optional customer copy will be sent when a customer email is provided. PrécédentSoumettreEnregistrer et reprendre plus tardThis furnace is configured as single stage. Two-stage and modulating checks do not apply. Select Next to continue to the diagnostic handoff. PrécédentEnvoyer le rapport de diagnosticEnregistrer et reprendre plus tard Votre saisie de formulaire a été enregistrée et un lien unique a été créé auquel vous pouvez accéder pour reprendre ce formulaire. Entrez votre adresse e-mail pour recevoir le lien par e-mail. Vous pouvez également copier et enregistrer le lien ci-dessous. Veuillez noter que ce lien ne doit pas être partagé et expirera dans 30 jours, après quoi votre soumission de formulaire sera supprimée. Copier le lien Courrier électronique * Envoyer le lien